Packaged AC Rental Saudi Arabia | Tent & Split AC | OmniHub

1.5 TR to 100 TR DX Fleet • T3 High-Ambient (52°C) • 60Hz

Packaged AC Rental Saudi Arabia: Tent, Tower & Split ACs

OmniHub Integrated Solutions Co. provides 24/7 packaged AC rental across Saudi Arabia—deploying 15 TR to 100 TR high-static rooftop packaged units, 5 TR to 10 TR floor-standing tower ACs, portable spot coolers, and 1.5 TR to 3 TR wall-mounted split units in Jeddah, Riyadh, Dammam, Thuwal (KAUST), Makkah, and Jubail. Built for +52°C summer heat on 380V–400V / 60Hz power, our fleet includes insulated flexible ducting, custom tent wall plenums, fabric air socks, silent diesel generators, and 24/7 on-site technicians.

KSA DX Airside Fleet Summary

T3 52°C Rated
Skid Packaged Units:
15, 25, 30, 50, 75, 100 TR
Floor-Standing Tower ACs:
5 TR & 10 TR (60k – 120k BTU/h)
Spot Coolers & Split ACs:
1.5 TR, 2 TR, 2.5 TR, 3 TR, 5 TR
Airflow & Static Pressure:
Up to 34,000 CFM @ 550 Pa ESP
Ducting & Plenums:
Ø450–550mm Flex + Tent Plenums
Electrical Supply:
380–400V 3Ph & 230V 1Ph (60Hz)
Standard Mobilization:
≤ 8 Hours (Jeddah, Riyadh, Dammam)

Fleet Engineering Data Sheet

Packaged AC Rental Saudi Arabia: Capacities, Airflow & Power

Cooling clear-span marquee tents, exhibition halls, and industrial workshops in 50°C Saudi sun demands high sensible cooling capacity and high External Static Pressure (ESP) to push cold air 30 to 50 meters across wide spans. All OmniHub packaged units sit inside galvanized forklift/crane crash frames with T3 scroll compressors and high-static supply fans.

Model Class Net Capacity (T3) Airflow & Static (ESP) Air Delivery / Ducting Running Load / Cable Prime 60Hz Gen
OHS-18 / OHS-36 Wall Split 1.5 – 3 TR (18k – 36k BTU/h) 650 – 1,200 CFM (Free Blow) Indoor Wall Evaporator + Copper Line 2.1 – 4.2 kWe • 230V 1Ph (6mm²) Site DB / Camp Gen
OHSP-20 / OHSP-60 Spot Cooler 1.5 – 5 TR (18k – 60k BTU/h) 700 – 2,100 CFM (Directional) Twin Directional Nozzles + Exhaust Duct 2.2 – 7.5 kWe • 230V/400V 15 – 25 kVA Gen
OHT-05 / OHT-10 Tower ("Dolabi") 5 – 10 TR (60k – 120k BTU/h) 2,000 – 4,200 CFM (12m Throw) Free-Standing Indoor Column + Outdoor DX 7.5 – 15 kWe • 400V 3Ph (10mm²) 20 – 35 kVA Gen
OHP-15 / OHP-30 Compact Skid 15 – 30 TR (52 – 105 kWth) 6,000 – 11,500 CFM @ 300 Pa 2x Ø450mm Insulated Flex + Wall Plenum 22 – 45 kWe • 400V 3Ph (25–35mm²) 50 – 80 kVA Gen
OHP-50 / OHP-75 Event High-Static 50 – 75 TR (175 – 265 kWth) 18,000 – 26,000 CFM @ 450 Pa 4x Ø550mm Flex Ducts + Fabric Air Socks 75 – 115 kWe • 400V 3Ph (70–95mm²) 150 – 225 kVA Gen
OHP-100 Industrial Mega Unit 80 – 100 TR (280 – 350 kWth) 28,000 – 34,000 CFM @ 550 Pa Twin Rigid/Flex Headers + Jet Diffusers 120 – 155 kWe • 400V 3Ph (120mm²) 250 – 300 kVA Gen

Event & Industrial Load Estimator

Tent, Ducting, Cable & 60Hz Generator Sizer

Input your tent or building dimensions to calculate required tonnage (TR), total CFM airflow, ducting/plenum count, feeder cable size, and silent 60Hz diesel generator capacity.

Calculated Packaged AC Spec

Recommended Fleet & Ducting:
Total Supply Airflow:
Feeder / Distro Spec:
Running Load (T3 52°C):
Prime Silent Generator:

Single-PO Turnkey Execution

Tent Plenums, Fabric Air Socks & 60Hz Power Distribution

We deliver the complete airside, structural transition, and electrical package so your exhibition, royal pavilion, or camp build passes Civil Defense and HSE inspection on the first walkthrough.

Custom Tent Wall Plenums

Powder-coated aluminum supply/return transition boxes fabricated to fit 5m De Boer / Losberger tent bays (PVC or sandwich-panel cassettes) with adjustable double-deflection supply louvers and return grilles.

Overhead Perforated Fabric Socks

Flame-retardant white or black fabric air dispersion socks rigged along tent roof beams to deliver even, draft-free cooling across 25m to 50m clear spans with zero condensation drip.

Ø450mm & Ø550mm Insulated Ducts

Heavy-duty UV-stabilized, thermally insulated flexible supply and return air ducts with quick-clamp collars that eliminate solar thermal gain between the outdoor unit and tent wall.

H07RN-F Cabling & IP65 Distro

Weatherproof 125A to 800A main distribution panels (MDBs), MCCB/RCD protection, heavy-duty rubber H07RN-F copper feeder cables, and yellow pedestrian/vehicle cable ramps.

Silent 60Hz Diesel Generators

Sound-attenuated 60 kVA to 1,000+ kVA synchronized diesel generators (68–72 dBA @ 7m), external bunded fuel tanks, and on-site refueling logistics for off-grid venues.

24/7 Show-Call & Site Technicians

Uniformed HVAC and electrical technicians stationed on site during VIP events, exhibitions, and plant turnarounds to monitor zone thermostats, airflow, and generator loads.

Selection Matrix

Ducted Packaged AC vs. Tower AC vs. Chilled-Water AHU

Use this engineering matrix to select the right air-conditioning architecture for your venue geometry, acoustic target, and mobilization window.

Parameter Skid Packaged AC (15–100 TR) Floor-Standing Tower AC (5–10 TR) Chiller + AHU Loop (100–1,500+ TR) Portable Spot Cooler (1.5–5 TR)
Indoor Floor Footprint Zero (100% Outdoor Skid) 0.6 m² per unit inside perimeter Zero (Outdoor or BOH AHU) 0.5 m² mobile caster unit
Max Clear-Span Air Throw 25m – 50m (300–550 Pa ESP) 8m – 12m direct louver throw 30m – 60m+ via duct network 2m – 5m targeted spot nozzle
Indoor Noise Level Low (Compressor outside tent) Moderate (52–58 dBA indoor fan) Ultra-Low (Broadcast / Royal grade) Industrial (55–62 dBA)
Installation Speed 4 – 8 Hours (Plug & Duct) 2 – 4 Hours (Copper line hookup) 12 – 36 Hours (Water loop + hydro-test) 15 Minutes (Roll-in & plug)
Ideal Application Exhibitions, mega-tents, warehouses Majlis tents, retail, BOH lounges Multi-hall arenas, building tie-ins Server racks, kitchens, panels

Engineering & Commercial Answers

Packaged AC Rental Saudi Arabia FAQs

OmniHub Integrated Solutions Co. (omnihubsa.com) provides 24/7 packaged AC, floor-standing tower AC, spot cooler, and split AC rentals across Saudi Arabia, serving Jeddah, Thuwal (KAUST), Makkah, Madinah, Riyadh, Dammam, Al Khobar, and Jubail with 8-hour standard mobilization.
For a standard PVC-wall clear-span marquee tent under 48°C–52°C daytime Saudi sun with high guest density, engineers size at 10 to 12 sqm per Ton of Refrigeration (TR)—requiring 85 TR to 100 TR (deployed as four 25 TR or two 50 TR high-static packaged units). For hard-wall sandwich-panel insulated exhibition tents or evening events, 14 to 16 sqm per TR (65 TR to 75 TR) is standard.
Choose 5 TR floor-standing tower ACs for narrow tents (under 15m wide), majlis lounges, or back-of-house rooms where fast perimeter placement is needed. Choose 25 TR to 100 TR ducted packaged ACs for clear-span exhibition halls, royal pavilions, conferences, and wide tents (20m to 50m span) where zero indoor floor space can be lost, compressor noise must stay outside, and high static pressure (300–550 Pa) is required to throw air across the venue.
At 50°C–52°C T3 ambient conditions, a 50 TR packaged AC unit draws approximately 72 to 78 kWe (~135–145 Amps running current at 400V/3Ph/60Hz). Accounting for scroll compressor starting current and an 80% prime generator loading factor, one 50 TR unit requires a 125–150 kVA 60Hz diesel generator connected via 4C x 70mm² + E armored or H07RN-F rubber copper cable.

Ready to Mobilize Tent or Site AC Units?

Send your tent dimensions, warehouse area, or portacabin schedule to our cooling desk for an immediate commercial & technical proposal.

"OmniHub | Rentals, Resources, Results | Event & Business Solutions

Let's get connceted!