Packaged AC Rental Saudi Arabia | Tent & Split AC | OmniHub

1.5 TR to 100 TR DX Fleet • T3 High-Ambient (52°C) • 60Hz

Packaged AC Rental Saudi Arabia: Tent, Tower & Split ACs

OmniHub Integrated Solutions Co. provides turnkey packaged AC rental in Saudi Arabia—deploying 15 TR to 100 TR high-static rooftop packaged units, 5 TR to 10 TR floor-standing tower ACs, and 1.5 TR to 3 TR wall-mounted split units across Jeddah, Riyadh, Dammam, Thuwal (KAUST), Makkah, and Jubail. Engineered for +52°C T3 summer ambient heat on 380V–400V / 60Hz power, our fleet includes insulated flexible ducting, custom tent wall plenums, overhead fabric air socks, silent diesel generators, and 24/7 on-site HVAC technicians.

DX Airside Fleet Summary

T3 52°C Rated
Packaged Rooftop Units:
15, 25, 30, 50, 75, 100 TR
Floor-Standing Tower ACs:
5 TR & 10 TR (60k – 120k BTU/h)
Cabin Split AC Units:
1.5 TR, 2 TR, 2.5 TR, 3 TR
Airflow & Static Pressure:
Up to 34,000 CFM @ 550 Pa ESP
Ducting & Air Distribution:
Ø450–600mm Flex + Fabric Socks
Electrical Supply:
380–400V 3Ph & 230V 1Ph (60Hz)
Standard Mobilization:
≤ 8 Hours (Jeddah, Riyadh, Dammam)

Technical Fleet Breakdown

Packaged AC Rental Saudi Arabia: Capacities, Airflow & Power

Cooling an uninsulated marquee tent or warehouse in 50°C Saudi sun requires high sensible cooling capacity and high External Static Pressure (ESP) to throw conditioned air 30 to 50 meters across wide spans. Our skid-mounted packaged units and free-standing towers are built specifically for rapid event, commercial, and industrial deployment.

Equipment Tier Cooling Capacity Nominal Airflow / ESP Air Delivery Method Electrical / Gen Size Best For
Wall-Mounted Split AC 1.5 – 3 TR (18k – 36k BTU) 650 – 1,200 CFM (Free Blow) Indoor Wall Evaporator 230V / 1Ph / 60Hz (2–4 kWe) Portacabins, site offices, guardhouses
Floor-Standing Tower ("Dolabi") 5 – 10 TR (60k – 120k BTU) 2,000 – 4,200 CFM (Long Throw) Direct Louvered JetPlenum 380–400V / 3Ph / 60Hz (7.5–15 kWe) VIP majlis, retail pop-ups, server rooms
Compact Skid Packaged AC 15 – 30 TR (52 – 105 kWth) 6,000 – 11,500 CFM @ 300 Pa Ø450mm Insulated Flex Duct + Plenum 22 – 45 kWe • 50–80 kVA Gen Medium marquees, dining tents, workshops
High-Static Event Packaged AC 50 – 75 TR (175 – 265 kWth) 18,000 – 26,000 CFM @ 450 Pa Ø550mm Flex Ducts + Fabric Air Socks 75 – 115 kWe • 150–200 kVA Gen Clear-span mega-tents, exhibitions, galas
Industrial Mega Packaged AC 80 – 100 TR (280 – 350 kWth) 28,000 – 34,000 CFM @ 550 Pa Twin Supply Headers + High-Velocity Nozzles 120 – 155 kWe • 250–300 kVA Gen Warehouses, hangars, royal pavilions

Event & Site Load Estimator

Tent, Exhibition & Site Office AC Sizer

Calculate your required tonnage (TR), total CFM airflow, recommended unit configuration, and 60Hz diesel generator capacity for Saudi summer conditions.

Calculated Event / Site Spec

Recommended Fleet Configuration:
Total Conditioned Airflow:
Estimated Electrical Load:
Recommended Prime Generator:

Zero-Footprint Venue Integration

Custom Plenums, Fabric Air Socks & Silent Power

Event producers and facility managers can't afford ugly duct runs, noisy compressors inside VIP halls, or tripped circuit breakers during a keynote speech. OmniHub handles the complete airside and electrical build-out.

Custom Tent Wall & Window Plenums

Powder-coated aluminum supply/return transition boxes that slot directly into clear-span tent wall bays (PVC or glass/hard-wall panels) with double-deflection grilles—keeping 100% of the AC machinery outside the tent perimeter.

Overhead Perforated Fabric Air Socks

Flame-retardant white or black fabric ducting suspended along tent roof beams to distribute cold air evenly across 25m–50m spans without cold drafts or condensation dripping on guests.

Ø450mm–600mm Insulated Flex Ducts

Heavy-duty UV-resistant, glass-wool insulated flexible supply and return air ducts that prevent solar heat gain between the outdoor packaged unit and the venue entry point.

60Hz Sound-Attenuated Generators

Synchronized 100 kVA to 1,000+ kVA silent diesel generators, rubber-sheathed H07RN-F armored cables, weatherproof IP65 distribution panels, and heavy-duty cable ramps.

Camp & Portacabin Split AC Fleets

Bulk rental of 1.5 TR to 3 TR wall-mounted split units and 5 TR floor-standing towers for construction camps, turnaround offices, and temporary clinics—installed with copper lines and condensate drainage.

24/7 On-Site Show & Site Technicians

Uniformed HVAC and electrical technicians stationed on site throughout live events, exhibitions, and industrial shutdowns to monitor zone temperatures and balance airflow.

Event & Industrial Cooling Answers

Packaged & Tent AC Rental FAQs

For an uninsulated or PVC-roofed marquee tent in 48°C–52°C Saudi summer heat with high guest density, engineers size at 10 to 12 sqm per Ton of Refrigeration (TR)—requiring 85 TR to 100 TR of cooling (typically deployed as four 25 TR or two 50 TR high-static packaged AC units). For hard-wall insulated exhibition tents or winter evening events, 14 to 16 sqm per TR (65 TR to 75 TR) is sufficient.
5 TR floor-standing tower ACs ("Dolabi" units) sit inside the room or tent perimeter while their outdoor condenser sits outside connected by copper refrigerant lines; they are fast to install for smaller tents, majlis lounges, and back-of-house zones. 25 TR to 100 TR packaged AC units sit completely outside the venue on heavy-duty skids and push conditioned air through insulated flexible ducts, wall plenums, or ceiling fabric air socks—saving 100% of indoor floor space and keeping compressor noise outside.
At T3 Saudi summer ambient conditions (up to 52°C), DX packaged AC units draw roughly 1.45 to 1.55 kWe per TR. For 100 TR of total cooling (e.g., four 25 TR packaged units with sequenced compressor starting), the continuous running load is ~150 kWe, requiring a 250 kVA to 300 kVA 400V/60Hz prime diesel generator.
We supply custom-fabricated aluminum supply/return transition boxes (plenums) that replace standard PVC side-wall panels or fit cleanly under sandwich-panel wall bays, plus overhead perforated fabric air socks suspended from the tent mainframes for draft-free, uniform cooling across 20m to 50m spans.
Yes. For project camps, turnaround shutdowns, and temporary site offices across Jeddah, Thuwal, Riyadh, Dammam, and Jubail, we rent and install 1.5 TR, 2 TR, and 3 TR T3 wall-mounted split ACs and 5 TR freestanding units on monthly and multi-month contracts, including copper piping, brackets, drainage, and maintenance.

Book Your Event or Site AC Fleet Today

Share your tent dimensions, warehouse area, or portacabin count—our team will deliver the AC units, ducting, generators, and technicians under one PO.

"OmniHub | Rentals, Resources, Results | Event & Business Solutions

Let's get connceted!